Common electrical components in the distribution cabinet


Release time:

2021-12-06

【Summary】 A comprehensive collection of commonly used electrical components in distribution cabinets! Do you recognize them? Circuit breakers, contactors, intermediate relays, thermal relays, buttons, indicator lights, universal switches, and limit switches are the eight most common components in electrical control circuits. The editor introduces the principles and applications of commonly used electrical components in a visually rich manner, helping to understand their roles in electrical circuits to grasp their usual operating conditions. 1. Circuit Breaker Low-voltage circuit breakers, also known as automatic air switches, can be manually switched and are used to distribute electrical energy, infrequently start asynchronous motors, and protect power lines and motors. They can automatically cut off the circuit when severe overloads, short circuits, or undervoltage faults occur. The character symbol for circuit breakers is: QF The graphic symbol for circuit breakers is: 2. Contactor Contactors consist of an electromagnetic mechanism and a contact system. The most common coil voltages for stainless steel distribution cabinet contactors are AC220V, AC380V, and DC220V. The electromagnetic mechanism of the contactor consists of a coil, a moving iron core (armature), and a static iron core; the contact system consists of main contacts and auxiliary contacts, with main contacts used to switch the main circuit and auxiliary contacts used in control circuits. The character symbol for contactors is: KM The graphic symbol for contactors is: 3. Thermal Relay Thermal relays operate based on the thermal effect produced by current passing through the component, functioning as a time-delay relay. The character symbol for thermal relays is: FR The graphic symbol for thermal relays is: 4. Intermediate Relay The principle of intermediate relays is to convert one input signal into multiple output signals or to amplify the signal (i.e., increase the relay contact capacity). The Shanghai distribution cabinet is essentially a voltage relay, but it has more contacts (up to 8 pairs), with contact capacities reaching 5-10A and sensitive operation. When the number of contacts in other electrical devices is insufficient, intermediate relays can be used to expand their number of contacts, and they can also be used to extend the capacity of electrical circuits. The character symbol for intermediate relays is: KA The graphic symbol for intermediate relays is: 5. Button In practical applications, buttons are usually selected based on the required number of contacts, the usage scenario, and color. Common series buttons like LA18, LA19, LA20 are suitable for AC500V, DC440V, with a rated current of 5A, controlling power in AC300W, DC70W control circuits. The character symbol for buttons is: SB The graphic symbol for buttons is: Button color requirements: (1) The "Stop" button and "Emergency Stop" button must be red. When the red button is pressed, the equipment must stop running or cut off power. (2) The color of the "Start" button is green. (3) The buttons for alternating actions of "Start" and "Stop" must be black, white, or gray; red and green buttons must not be used. (4) The "Momentary" button must be black. (5) The "Reset" button (if there is a reset button for the protective relay) must be blue; if the reset button also has a stop function, it must be red. 6. Indicator Light The functions of indicator lights: (1) Indicate the running or stopping status of the equipment. (2) Monitor whether the power supply of control devices is normal. (3) Use red lights to monitor whether the tripping circuit is normal and green lights to monitor whether the closing circuit is normal. 7. Switch Universal switches consist of an operating mechanism, panel, handle, and several contact seats. The character symbol for universal switches is: SA The graphic symbol for universal switches is: The on/off status of each contact when the handle is turned to different positions is indicated by black dots; a dot indicates the contact is closed, while the absence of a dot indicates the contact is open. 8. Limit Switch The character symbol for limit switches is: SQ

                                Distribution cabinet commonly used electrical components

Circuit breakers, contactors, intermediate relays, thermal relays, buttons, indicator lights, universal switches, and limit switches are the eight most common components in electrical control circuits. The author introduces the principles and applications of commonly used electrical components in a graphic and textual manner, helping to understand their roles in electrical circuits to grasp the operational status of these components.

Stainless Steel Distribution Cabinet

1. Circuit Breaker

Low-voltage circuit breakers, also known as automatic air switches, can be manually switched and are used to distribute electrical energy, start asynchronous motors infrequently, and protect power lines and motors. They can automatically cut off the circuit when serious overloads, short circuits, or undervoltage faults occur.

The character symbol for circuit breakers is: QF

The graphic symbol for circuit breakers is:

2. Contactor

Contactors consist of two parts: an electromagnetic mechanism and a contact system.Stainless Steel Distribution CabinetThe most common coil voltages for contactors are AC220V, AC380V, and DC220V.The electromagnetic mechanism of the contactor consists of a coil, a moving iron core (armature), and a static iron core; the contact system of the contactor consists of main contacts and auxiliary contacts, with the main contacts used to switch the main circuit and auxiliary contacts used in control circuits.

The character symbol for contactors is: KM

The graphic symbol for contactors is:

3. Thermal Relay

Thermal relays operate based on the thermal effect produced by current passing through the component.

The character symbol for thermal relays is: FR

The graphic symbol for thermal relays is:

4. Intermediate Relay

The principle of intermediate relays is to convert one input signal into multiple output signals or to amplify the signal (i.e., increase the relay contact capacity).Shanghai Distribution Cabinet, in essence, it is a voltage relay, but it has more contacts (up to 8 pairs), and the contact capacity can reach 5-10A, with sensitive action.

When the number of contacts of other electrical devices is insufficient, intermediate relays can be used to expand their number of contacts, and they can also be used to extend the contact capacity.

The character symbol for intermediate relays is: KA

The graphic symbol for intermediate relays is:

5. Button

In practical applications, buttons are usually selected based on the required number of contacts, the usage scenario, and color. Common series buttons such as LA18, LA19, LA20, etc., are suitable for AC500V, DC440V, with a rated current of 5A, controlling power in AC300W, DC70W control circuits.

The character symbol for buttons is: SB

The graphic symbol for buttons is:

Button color requirements:

(1) The "Stop" button and the "Emergency Stop" button must be red.Custom Distribution CabinetWhen the red button is pressed, the device must stop running or cut off power.

(2) The color of the "Start" button is green.

(3) The buttons that alternate between "Start" and "Stop" must be black, white, or gray; red and green buttons must not be used.

(4) The "Momentary" button must be black.

(5) The "Reset" button (if there is a reset button for the protective relay) must be blue; if the reset button also has a stop function, it must be red.

6. Indicator Light

The function of the indicator light:

(1) Indicates the running or stopping status of the device.

(2) Monitors whether the power supply of the control device is normal.

(3) Uses a red light to monitor whether the tripping circuit is normal and a green light to monitor whether the closing circuit is normal.

7. Switch

The universal switch consists of an operating mechanism, a panel, a handle, and several contact seats.

The character symbol for the universal switch is: SA

The graphic symbol for the universal switch is:

The on/off status of each contact when the handle is turned to different positions is indicated by black dots; a black dot indicates that the contact is closed, while the absence of a black dot indicates that the contact is open.

8. Limit Switch

The character symbol for limit switches is: SQ