Common electrical components in the distribution cabinet


Release time:

2020-09-07

【Summary】1. Circuit Breaker Low-voltage circuit breakers, also known as automatic air switches, can be manually switched and are used to distribute electrical energy, start asynchronous motors infrequently, and protect power lines, motors, etc. They can automatically cut off the circuit when serious overloads, short circuits, or undervoltage faults occur. The character symbol for circuit breakers is: QF The graphic symbol for circuit breakers is: 2. Contactor The contactor consists of two parts: an electromagnetic mechanism and a contact system. The most common coil voltages for stainless steel distribution cabinet contactors are AC220V, AC380V, and DC220V. The electromagnetic mechanism of the contactor consists of a coil, a moving iron core (armature), and a static iron core; the contact system of the contactor consists of main contacts and auxiliary contacts, where the main contacts are used to switch the main circuit, and the auxiliary contacts are used in the control circuit. The character symbol for contactors is: KM The graphic symbol for contactors is: 3. Thermal Relay The thermal relay operates based on the principle of thermal effects produced by current passing through components, acting with a time delay. The character symbol for thermal relays is: FR The graphic symbol for thermal relays is: 4. Intermediate Relay The principle of the intermediate relay is to convert one input signal into multiple output signals or to amplify the signal (i.e., increase the relay contact capacity). The Shanghai distribution cabinet is essentially a voltage relay, but it has more contacts (up to 8 pairs), and the contact capacity can reach 5-10A, with sensitive operation. When the number of contacts of other electrical devices is insufficient, an intermediate relay can be used to expand their number of contacts, and it can also be used to extend the capacity of electric shock. The character symbol for intermediate relays is: KA The graphic symbol for intermediate relays is: 5. Button In practical applications, buttons are usually selected based on the required number of contacts, the usage scenario, and color. Common series buttons like LA18, LA19, LA20 are suitable for AC500V, DC440V, with a rated current of 5A, and control power in control circuits of AC300W, DC70W. The character symbol for buttons is: SB The graphic symbol for buttons is: Button color requirements: (1) The "Stop" button and the "Emergency Stop" button must be red. When the red button is pressed, the equipment must stop running or cut off power. (2) The color of the "Start" button is green. (3) The button for alternating actions of "Start" and "Stop" must be black, white, or gray; red and green buttons must not be used. (4) The "Jog" button must be black. (5) The "Reset" button (if there is a reset button for the protective relay) must be blue; if the reset button also has a stop function, it must be red. 6. Indicator Light The functions of the indicator light: (1) Indicate the running or stopping status of the equipment. (2) Monitor whether the power supply of the control device is normal. (3) Use a red light to monitor whether the tripping circuit is normal and a green light to monitor whether the closing circuit is normal. 7. Selector Switch The universal selector switch consists of an operating mechanism, a panel, a handle, and several contact seats. The character symbol for the universal selector switch is: SA The graphic symbol for the universal selector switch is: The on/off state of each contact when the handle is turned to different positions is indicated by black dots; a dot indicates the contact is closed, while the absence of a dot indicates the contact is open. 8. Limit Switch The character symbol for limit switches is: SQ

                                        A large collection of commonly used electrical components in the distribution cabinet! Do you recognize them?

Circuit breakers, contactors, intermediate relays, thermal relays, buttons, indicator lights, universal transfer switches, and limit switches are the eight most common components in electrical control circuits. The editor introduces the principles and applications of commonly used electrical components in a pictorial manner, helping to understand their roles in electrical circuits to grasp the operational status of these components.

Stainless Steel Distribution Cabinet

1. Circuit Breaker

Low-voltage circuit breakers, also known as automatic air switches, can be manually switched and are used to distribute electrical energy, not frequently start asynchronous motors, and protect power lines, motors, etc. They can automatically cut off the circuit when serious overloads, short circuits, or undervoltage faults occur.

The character symbol for circuit breakers is: QF

The graphic symbol for circuit breakers is:

2. Contactor

Contactors consist of two parts: an electromagnetic mechanism and a contact system.Stainless Steel Distribution CabinetThe most common coil voltages for contactors are AC220V, AC380V, and DC220V.The electromagnetic mechanism of the contactor consists of a coil, a moving iron core (armature), and a static iron core; the contact system of the contactor consists of main contacts and auxiliary contacts, with the main contacts used to switch the main circuit and auxiliary contacts used in control circuits.

The character symbol for contactors is: KM

The graphic symbol for contactors is:

3. Thermal Relay

Thermal relays operate based on the thermal effect produced by current passing through the component, functioning as time-delay relays.

The character symbol for thermal relays is: FR

The graphic symbol for thermal relays is:

4. Intermediate Relay

The principle of intermediate relays is to convert one input signal into multiple output signals or to amplify the signal (i.e., increase the relay contact capacity).Shanghai Distribution Cabinet, in essence, it is a voltage relay, but it has more contacts (up to 8 pairs), and the contact capacity can reach 5-10A, with sensitive action.

When the number of contacts of other electrical devices is insufficient, intermediate relays can be used to expand their number of contacts, and they can also be used to extend the contact capacity.

The character symbol for intermediate relays is: KA

The graphic symbol for intermediate relays is:

5. Button

In practical applications, buttons are usually selected based on the required number of contacts, the usage scenario, and color. Common series buttons like LA18, LA19, LA20, etc., are suitable for AC500V, DC440V, with a rated current of 5A, controlling power in AC300W, DC70W control circuits.

The character symbol for buttons is: SB

The graphic symbol for buttons is:

Button color requirements:

(1) The "Stop" button and the "Emergency Stop" button must be red.Custom Distribution CabinetWhen the red button is pressed, it must stop the equipment from running or cut off the power.

(2) The color of the "Start" button is green.

(3) The buttons that alternate between "Start" and "Stop" must be black, white, or gray, and red and green buttons must not be used.

(4) The "Momentary" button must be black.

(5) The "Reset" button (if there is a reset button for the protective relay) must be blue; if the reset button also has a stop function, it must be red.

6. Indicator Light

The function of the indicator light:

(1) Indicates the running or stopping status of the device.

(2) Monitors whether the power supply of the control device is normal.

(3) Uses a red light to monitor whether the tripping circuit is normal and a green light to monitor whether the closing circuit is normal.

7. Transfer Switch

The universal transfer switch consists of an operating mechanism, panel, handle, and several contact seats.

The character symbol for universal transfer switches is: SA

The graphic symbol for universal transfer switches is:

The on/off state of each contact when the handle is turned to different positions is indicated by black dots; a black dot indicates that the contact is closed, while the absence of a black dot indicates that the contact is open.

8. Limit Switch

The character symbol for limit switches is: SQ

 